Description
VC01+Features:
1. Simulating output from thermocouple(TC), R/S/K/E/J/T/B/N
2. Simulating output from resistance(400/4000 ohm) or RTD (Pt10/100/200/500/1000, Cu10/Cu50)
3. DCV output(100mV/1000mV)
4. Can display C or F.
Specifications:
Output
Range
Output range
Resolution
Accuracy
Expalnation
Voltage DCV
100mV
-10.00 ~110.00mV
0.01mV
±0.05% Setting value ±30uV
The max. output current ±5mA
1000mV
-100.00~1100.0mV
0.1mV
±0.05% Setting value ± 0.3mV
Resistance OHM
400Ω/4000
Ω
0.0~400.0Ω/0-4000
Ω
0.1Ω/1
Ω
±0.05% Setting value +0.2Ω/
±0.05% Setting value +2Ω
+-0.5 to +-3mA/ +-0.05 to +-0.3mA exciting current, not including lead resistance
Thermocouple TC
R
-40~
1760
℃
1
℃
±0.05% Setting value ±
3
℃
(≤
100
℃
)
Adopt the ITS-90
S
-20~
1760
℃
1
℃
±0.05% Setting value ±
2
℃
(
>
100
℃
)
B
400~
1800
℃
±0.05% Setting value ±
3
℃
(400~
600
℃
)
temperature standard
±0.05% Setting value ±
2
℃
(
>
600
℃
)
E
-200.0~
1000.0
℃
0.1
℃
±0.05% Setting value ±
2
℃
(≤
-100
℃
)
(Note 3)
K
-200.0~
1370
℃
0.1
℃
J
-200.0~
1200.0
℃
0.1
℃
±0.05% Setting value ±
1
℃
(
>
-100
℃
)
T
-200.0~
400.0
℃
0.1
℃
N
-200.0~
1300.0
℃
0.1
℃
Thermo-resistance RTD
Pt10 385/ Pt100 385/
Pt200 385/
Pt500 385/
Pt1000 385
-200.0-850.0C/
-200.0~
850.0C/
-200-630C/
-200-630C/
-200.0-630.0C
0.1
C
±0.05% Setting value ±
0.6
℃
Adopt the PT100-385
(Note 1.2)
Cu10/Cu50
-10.0-250.0C/
-50.0~
150.0
C
0.1
C
Note:
1.Not including the accessorial lead resistance
2.The max. voltage between output terminals 32Vpk, the max. current between output terminals 5mA
3.Not including the accuracy of inner temperature compensatory transducer.
The range of inner temperature compensatory transducer:-10
-50°C
, error ≤
0.5°C from 18-28C, others, error +-1C,
compensatory time for cool end is 10S per time.
4.Temperature coefficient
: 0.1 x basic accuracy/C
(
0°C
-18°C
,
28°C
-50°C
)
5. Output terminals protection: 50mA/60V complex film
General features:
Work temperature and humidity: 0-50C, =<80%RH; 40-50C, =<70% RH
Storage temperature and humidity: -25-60C, =<90%RH
Conforms to EN61010-1:2001, EN60068-2-64:2008, IEC 60068-2-32: 2008
Power supply: 2x1.5V AA batterey(not included)
Size: 180 x 90 x 47mm
Weight: 550g
Accessories:
a pair test leads, PDF English manual.
Note:
1.W
ill ship
to
USA
via
DHL or Fedex
(not for PO Box or APO or FPO), delivery time is about
7 days.
2. Will ship via
express mail service
to Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea, Thailand, Malaysia, Indonesia, Philippine and Singapore customers.
3. Customers from other countries pls contact us in advance to confirm different shipping charges before you order.