-40%

Fluke 5320A Multifunction Electrical Tester Calibrator w/ HV Adapter / R Multi

$ 10559.47

Availability: 100 in stock
  • All returns accepted: ReturnsNotAccepted
  • Brand: Fluke
  • Condition: Used, good condition. Includes HV Adapter / R Multiplier

    Description

    What's included:
    Fluke 5320A
    Fluke 5320A HV Adapter / R Multiplier
    Nothing else is included, no other accessories are included aside from 2 items listed above.
    One corner is physically damaged however it does not seem to effect electronic
    performance
    at all.  Buttons and screen is in good shape, additional screen protector was added onto the unit that can easily be removed.  Minor wear around the outer casing.
    Passes self-test and basic test with a DMM.
    This is *not* the 5320A/VLC model and so does not include the following functions:
    AC/DC Voltage Calibrator (5320A/VLC only)
    Correction COMP Mode (Active Loop Compensation) (5320A/VLC only)
    Leakage Current Source Active Mode (5320A/VLC only)
    Note: Shipping cost **does not**, this would be extra based on the high-ticket costs for this item.
    From Fluke's Specification Sheet:
    General Specifications
    Warm-Up Time
    .........................................................30 minutes
    Specifications Confidence Level
    ..........................99 %
    Specifications Interval
    ............................................1 year
    Temperature Performance
    Operating Temperature ........................................18 to 28
    °
    C
    Calibration Temperature (tcal) ............................23
    °
    C
    Temperature Coefficient.......................................Temperature coefficient for temperature outside of Tcal
    ±
    5
    °
    C between
    +5
    °
    C to +40
    °
    C is 0.1 x /
    °
    C Storage Temperature ............................................-20 to +70
    °
    C
    Relative Humidity (operating)
    ..............................<70 % to 28
    °
    C
    Altitude
    Operating................................................................3,050 m (10,000 ft.)
    Storage....................................................................12,200 m (40,000 ft.)
    Dimensions
    ................................................................450 mm X 480 mm X 170 mm (17.7 in. X 18.9 in. X 6.7 in.)
    Weight
    ........................................................................18 kg (39.7 lb)
    Power Line
    .................................................................115/230 V ac (50/60 Hz)
    ±
    10 %, with the maximum voltage difference
    between Neutral and Protective Earth not exceeding 20 V.
    Power Consumption
    ................................................150 VA Maximum
    Safety Class
    ...............................................................Class I, Bonded Enclosure
    Electrostatic Discharge
    ..........................................This instrument meets class I for ESD requirements per EN 61326
    (Criteria A)
    W
    Fuse Protection
    AC mains input ......................................................2 A, 250 V for 230 V, Time delay (T2L250 V – 5 x 20 mm)
    4 A, 250 V for 115 V, Time delay (T4L250 V – 5 x 20 mm) RCD input ...............................................................3.15 A, 250 V, Fast (F3.15L250V – 5 x 20 mm)
    Meter amps (A) input............................................20 A, 500 V, Time delay (T20L500V – 6.3 x 32 mm) Loop/Line impedance input.................................4 A, 250 V, Time delay (T4L250V – 6.3 x 32 mm) Leakage current input ..........................................100 mA, 150V, Fast (F100mL150V – 5 x 20 mm)
    Low Resistance Source
    Total Range
    ...............................................................100 m
    Ω
    to 10 k
    Ω
    Resolution
    ..................................................................31⁄2 digits (continuously variable)
    Electrical Specifications
    Uncertainty and Maximum Ratings
    Range
    100 m
    Ω
    to 4.99
    Ω
    5 to 29.9
    Ω
    30 to 199.9
    Ω
    200 to 499
    Ω
    500
    Ω
    to 1.999 k
    Ω
    2 to 4.99 k
    Ω
    5 to 10 k
    Ω
    Resolution
    0.1 m
    Ω
    0.01
    Ω
    0.1
    Ω
    1
    Ω
    1
    Ω
    10
    Ω
    10
    Ω
    Maximum AC or DC Current
    [1]
    400 mA 250 mA 100 mA 45 mA 25 mA 10 mA 5 mA
    2-Wire Uncertainty
    [2]
    (tcal
    ±
    5
    °
    C)
    0.3 % + 25 m
    Ω
    0.2 % + 25 m
    Ω
    0.2 % + 25 m
    Ω
    0.2 %
    0.2 % 0.2 % 0.2 %
    4-Wire Uncertainty (tcal
    ±
    5
    °
    C)
    0.3 % + 10 m
    Ω
    0.2 % + 10 m
    Ω
    0.2 % + 10 m
    Ω
    0.2 %
    0.2 % 0.2 % 0.2 %
    orporation
    5320A Multifunction Electrical Tester Calibrator
    Notes:
    [1]  Test current can exceed 120 % of maximum current for up to 3 seconds. Terminals automatically disconnect if test current exceeds
    120 % of specified maximum current.
    [2]  Uncertainty is valid to 200 mW. For higher power rating, add 0.1 % per each 300 mW above 200 mW.
    Test Current Measurement
    Range
    ..........................................................................0 to 400 mA ac + dc rms
    Resolution
    ..................................................................1 mA
    Uncertainty
    ................................................................


    20


    R = set resistance between 0.5
    Ω
    to 10 k
    Ω
    .
    ⎜⎜ ⎟ +
    0.1

    mA


    R


    Nominal resistance
    .................................................<50 m
    Ω
    Maximum current
    ....................................................400 mA ac + dc rms
    Open Mode
    Nominal resistance
    .................................................30 M
    Ω ±
    20 %
    Maximum input voltage allowed
    .........................50 V ac + dc rms
    Test voltage reading
    ...............................................0 to 50 V ac + dc rms
    Resolution
    ..................................................................1 V
    Uncertainty
    ................................................................5 % + 2 V
    High Resistance Source
    Range
    ..........................................................................10 k
    Ω
    to 10 G
    Ω
    plus 100 G
    Ω
    single value selection.
    Resolution
    ..................................................................41⁄2 Digit (continuously variable for 10 k
    Ω
    to 10 G
    Ω
    range)
    Uncertainty and Maximum Ratings
    Range
    10.000 to 39.99 k
    Ω
    40.00 to 99.99 k
    Ω
    100.00 to 199.99 k
    Ω
    200.0 to 999.9 k
    Ω
    1.0000 to 9.999 M
    Ω
    10.000 to 999.9 M
    Ω
    1.0000 to 10.000 G
    Ω
    100 G
    Ω
    Resolution
    1
    Ω
    10
    Ω
    10
    Ω
    100
    Ω
    100
    Ω
    1 k
    Ω
    100 k
    Ω
    NA
    Maximum Voltage (ac + dc) Peak
    55 V 400 V 800 V 1100 V 1150 V 1575 V
    [2]
    1575 V
    [2]
    1575 V
    [2]
    Uncertainty
    [1]
    (tcal
    ±
    5
    °
    C)
    0.2 % 0.2 % 0.2 % 0.2 % 0.3 % 0.5 % 1.0 % 3.0 %
    [3]
    Notes:
    [1]  Uncertainty is valid to 500 volts. For test voltages above 500 V, add 0.1% for each 200 V above 500 V.
    [2]  Maximum test voltage with the supplied banana leads is 1000 Vrms. For higher voltages, use leads rated at 1575 V or above.
    [3]  Calibration value uncertainty is specified in the table. Nominal value is
    ±
    15 %.
    Test Voltage Measurement
    Range
    ..........................................................................0 to 2000 V dc peak
    Resolution
    ..................................................................1 V
    Uncertainty
    ................................................................1 % + 5 V for R above 1 M
    Ω
    1 % + 2 V for R below 1 M
    Ω
    Settling Time
    ............................................................2 seconds for input deviations of <5 %
    Test Current Measurement
    Range
    ..........................................................................0 to 9.9 mA dc
    Uncertainty
    ................................................................1.5 % + 5V/R A (where R is the selected resistance value)
    Settling time
    ..............................................................2 seconds (for voltage reading deviations < 5 %)
    Short Mode
    Nominal resistance
    .................................................<100
    Ω
    Maximum input current allowed
    .........................50 mA ac + dc rms
    Test current range
    ...................................................0 to 50 mA ac + dc rms
    Resolution
    ..................................................................0.1 mA
    Uncertainty
    ................................................................2 % + 0.5 mA
    Resistance Multiplier Adapter (x1000 multiplier)
    Resistance range
    .....................................................350 M
    Ω
    to 10 T
    Ω
    Range
    350.0 M
    Ω
    to 99.99 G
    Ω
    100.00 G
    Ω
    to 999.9 G
    Ω
    1.0000 T
    Ω
    to 10.000 T
    Ω
    Resolution
    100 k
    Ω
    10 M
    Ω
    100 M
    Ω
    Maximum Voltage (ac + dc) Peak
    10000 V 10000 V 10000 V
    Uncertainty (tcal
    ±
    5
    °
    C)
    1.0%+R
    [1]
    2.0%+R
    [1]
    3.0%+R
    [1]
    Uncertainty and Maximum Ratings
    Notes:
    [1] R is the uncertainty of resistor to be multiplied by 1000.
    Ground Bond Resistance Source
    Resistance Mode
    Range
    ..........................................................................25 m
    Ω
    to 1.8 k
    Ω
    Resolution
    ..................................................................16 discrete values
    Minimum test voltage/current
    ..............................10 V / 10 mA
    Test Current Measurement Range
    .......................0 to 40 A ac + dc rms
    Test Current Measurement Resolution
    ...............1 mA to 100 mA depending on resistance output and test current
    Uncertainty and Maximum Ratings
    Nominal Value
    25 m
    Ω
    50 m
    Ω
    100 m
    Ω
    330 m
    Ω
    500 m
    Ω
    1
    Ω
    1.8
    Ω
    5
    Ω
    10
    Ω
    18
    Ω
    50
    Ω
    100
    Ω
    180
    Ω
    500
    Ω
    1 k
    Ω
    1.8 k
    Ω
    Deviation from Nominal Value
    ±
    50 %
    ±
    50 %
    ±
    30 %
    ±
    20 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    ±
    10 %
    Absolute Uncertainty of Characterized Value (tcal
    ±
    5
    °
    C)
    ±
    5 m
    Ω ±
    5 m
    Ω ±
    5 m
    Ω
    ±
    7 m
    Ω
    ±
    8 m
    Ω ±
    10 m
    Ω ±
    18 m
    Ω ±
    30 m
    Ω ±
    60 m
    Ω ±
    100 m
    Ω ±
    300 m
    Ω ±
    500 m
    Ω ±
    1
    Ω ±
    2.5
    Ω ±
    5
    Ω ±
    10
    Ω
    Maximum Continuous Test
    Current
    [1]
    ACrms or DC
    30 A 28 A 25 A 14 A 10 A 8A
    6 A 3.2 A 2.0 A 1.5 A 0.8 A 0.5 A 0.25 A 0.1 A 0.05 A 0.025 A
    Maximum Short- term Test Current AC rms or DC
    [2]
    40A 40A 40A 40A 40A 40A 30A 21A 15A 10 A 5.0 A 3.0 A 1.35 A 0.6 A 0.3 A 0.15 A
    Test Current Uncertainty
    1.5 % + 0.7 A
    1.5 % + 0.5 A 1.5 % + 0.35 A 1.5 % + 0.3 A 1.5 % + 0.2 A 1.5 % + 150 mA 1.5 % + 100 mA 1.5 % + 70 mA 1.5%+50mA 1.5%+30mA 1.5%+20mA 1.5%+10mA 1.5 % + 5 mA
    1.5%+3 1.5%+2 1.5%+2
    mA mA mA
    Notes:
    [1]  Test currents up to 30 % of maximum continuous test current can be applied to the Calibrator with no time limitation. Test
    current between 30 % and 100 % of the maximum continuous test current can be applied to the Calibrator for a limited time. Minimum period of full current load is 45 seconds. The Calibrator calculates the allowed time period and when exceeded, the output connectors are disconnected.
    [2]  Maximum short term test current is defined as the rms value of halfwave or fullwave test current flowing through the UUT. Maximum time of test is 200 ms. A time interval of 200 ms represents 10 full waves of power line voltage at 50 Hz and 12 full waves at 60 Hz.
    Open Mode
    Nominal resistance
    .................................................>100 k
    Ω
    Maximum voltage
    ....................................................50 V ac + dc rms
    Test voltage range
    ...................................................0 to 50 V ac + dc rms
    Resolution
    ..................................................................1 V
    Uncertainty
    ................................................................2 % + 2 V
    Transfer Ground Bond Resistance Accuracy in m
    Ω
    UUT Test Current
    Transfer Mode
    Transfer GBR
    Marking
    (m
    Ω
    )
    on
    Display
    30 A
    ±
    0.8 m
    Ω ±
    0.9 m
    Ω
    -
    -
    28 A
    ±
    0.8 m
    Ω
    ±
    1.0 m
    Ω ±
    1.1 m
    Ω
    -
    25 A
    ±
    0.8 m
    Ω
    ±
    1.0 m
    Ω ±
    1.1 m
    Ω ±
    1.4 m
    Ω
    20 A
    ±
    0.9 m
    Ω
    ±
    1.0 m
    Ω ±
    1.2 m
    Ω ±
    1.4 m
    Ω
    14 A
    ±
    1.0 m
    Ω
    ±
    1.2 m
    Ω ±
    1.3 m
    Ω ±
    1.6 m
    Ω ±
    3.0 m
    Ω
    8A
    ±
    1.3 m
    Ω
    ±
    1.5 m
    Ω
    ±
    1.7 m
    Ω
    ±
    2.0 m
    Ω
    ±
    3.6 m
    Ω ±
    4.1m
    Ω±
    4.4m
    Ω±
    7.2m
    Ω
    50 0
    80 R1 120 R2 170 R3 420 R4 550 R5
    10 A
    ±
    1.2 m
    Ω
    3 A
    ±
    2.6 m
    Ω ±
    2.9 m
    Ω ±
    3.1 m
    Ω ±
    3.6 m
    Ω ±
    6.0 m
    Ω
    ----
    - - - - -
    ±
    1.4 m
    Ω ±
    1.5 m
    Ω ±
    1.8 m
    Ω ±
    3.3 m
    Ω
    Maximum and Minimum Applicable Test Currents from the Ground Bond Resistance Meter
    5320A Transfer GBR (m
    Ω
    ) UUT Minimum Test Current AC/DC (A) UUT Maximum Test Current AC/DC (A)
    50 3 30
    80 3 30 120 3 28 170 3 25 420 3 14 550 3 10
    Notes
    The minimum value of the indicated test current is 0.05 A.
    The transfer GBR indication as the main value on the display is shown when the test current is 3 A or greater.
    Line/Loop Impedance Source
    Range
    ..........................................................................25 m
    Ω
    to 1.8 k
    Ω
    Resolution
    ..................................................................16 discrete values
    Minimum test voltage/current
    ..............................10 V/10 mA
    Test Current Measurement
    Type of recognized test current
    ...........................Positive impulse (halfwave), negative impulse (halfwave), symmetrical
    (fullwave).
    Range
    ..........................................................................0 to 40 A ac + dc rms
    Resolution
    ..................................................................1 to 100 mA depending on test current and resistance output
    Prospective Fault Current
    Range
    ..........................................................................0 to 10 kA
    Correction Manual Mode
    Residual Impedance Range
    ...................................0 to 10
    Ω
    Resolution
    ..................................................................1 m
    Ω
    Uncertainty
    ................................................................Uncertainty in manual (MAN) mode is the uncertainty of selected
    resistance value. See table above. Also, the uncertainty of the manually entered correction should be taken into consideration.
    Correction Scan Mode
    Residual Impedance Range
    ...................................0 to 10
    Ω
    Resolution
    ..................................................................1 m
    Ω
    Uncertainty
    ................................................................(1 % +15 m
    Ω
    ) + uncertainty of selected resistance value.
    Leakage Current Source
    Range
    ..........................................................................0.1 to 30 mA
    Resolution:
    Passive Mode .........................................................10
    μ
    A setting, 1
    μ
    A measurement Differential Mode...................................................10
    μ
    A setting, 1
    μ
    A measurement Substitute Mode.....................................................10
    μ
    A
    Active Mode (5320A/VLC only)...........................10
    μ
    A
    Test Voltage:
    Passive Mode .........................................................60 to 250 V ac + dc rms Differential Mode...................................................60 to 250 V ac + dc rms Substitute Mode.....................................................10 to 250 V ac + dc rms Active Mode (5320A/VLC only)...........................50 to 100 V ac + dc rms
    Uncertainty:
    Passive Mode .........................................................0.3 % + 2
    μ
    A ac + dc rms Differential Mode...................................................0.3 % + 2
    μ
    A ac + dc rms
    Test uncertainty can be influenced by power line voltage instability Substitute Mode.....................................................0.3 % + 2
    μ
    A ac + dc rms
    Active Mode (5320A/VLC only)...........................0.3 % + 1
    μ
    A ac + dc rms
    RCD (Residual Current Device)
    Trip Current Range
    :
    0.5 X I and 1 X I Mode..........................................3 to 3000 mA in 1 mA steps 1.4 X I and 2 X I Mode..........................................3 to 1500 mA in 1 mA steps 5 X I Mode ..............................................................3 to 600 mA in 1 mA steps
    Trip Current Measurement Resolution
    ...............1
    μ
    A on 30 mA range 10
    μ
    A on 300 mA range
    100
    μ
    A on 3A range
    Uncertainty
    :
    0.5 X I and 1 X I Mode..........................................1 % rms 1.4 X I and 2 X I Mode..........................................2 % rms 5 X I Mode ..............................................................5 % rms
    Trip Time Range
    ......................................................10 to 5000 ms
    Trip Time Uncertainty
    ............................................0.02 % + 0.25 ms
    Series Resistance
    .....................................................0.025
    Ω
    , 0.05
    Ω
    , 0.1
    Ω
    , 0.33
    Ω
    , 0.5
    Ω
    , 1
    Ω
    , 1.8
    Ω
    , 5
    Ω
    , 10
    Ω
    , 18
    Ω
    ,
    50
    Ω
    , 100
    Ω
    , 180
    Ω
    , 500
    Ω
    , 1000
    Ω
    , 1800
    Ω
    Line/Touch Voltage Range
    ....................................250 V
    Line/Touch Voltage Uncertainty
    ..........................5 % + 3 V
    Multimeter
    Voltage
    Range
    ..........................................................................0 to 1100 V ac rms or dc
    Resolution
    ..................................................................41⁄2 digits
    Internal Ranges
    ........................................................10, 100, and 1100 V (Autoranging only)
    Frequency Range
    .....................................................DC, 20 Hz to 2 kHz
    Input Resistance
    ......................................................10 M
    Ω ±
    1 %
    Time Constant
    ..........................................................1.5 s
    Readings/Second
    .....................................................2
    Measurement Category
    ..........................................1000 V CAT I, 300 V CAT II
    Range
    10 V 100 V 1100 V
    AC/DC Voltage Uncertainty Resolution
    0.001 V 0.01 V 0.1 V
    Uncertainty
    ±
    (% of Reading + mV)
    0.15 % + 5 0.20 % + 50 0.20 % + 550
    Current
    Range
    ..........................................................................0 to 20 A continuous, 30 A for up to 30 minutes, ac rms or dc
    Resolution
    ..................................................................41⁄2 digits
    Internal Ranges
    ........................................................300 mA, 3 and 30 A (Autoranging only)
    Frequency Range
    .....................................................DC, 20 to 400 Hz
    Time Constant
    ..........................................................1.5 s
    Readings/Second
    .....................................................2
    Range
    300 mA 3 A 30 A
    AC/DC Current Uncertainty Resolution
    0.1 mA 1 mA 10 mA
    Uncertainty
    ±
    (% of Reading + mV)
    0.15 % + 0.15 0.15 % + 1.5 0.30 % + 15
    Hipot Leakage Current Measurement Mode
    Range
    ..........................................................................0 to 300 mA ac rms or dc
    Resolution
    ..................................................................4 1/2 digits
    Frequency range
    ......................................................DC, 20 Hz to 400 Hz
    Time constant
    ...........................................................1.5 s
    Readings/second
    .....................................................2
    Phantom Power
    Range
    ..........................................................................0 to 33 kVA
    Resolution
    ..................................................................3 digits
    Uncertainty
    ................................................................
    2 2
    where V
    unc
    is specified uncertainty of measured voltage and I
    unc
    is specified uncertainty of measured current.
    Range
    300 uA 3 mA 30 mA 300 mA
    Resolution
    0.01
    μ
    A 0.1
    μ
    A 1
    μ
    A 10
    μ
    A
    Uncertainty
    ±
    (% of reading +
    μ
    A)
    0.3 % + 0.21
    0.2 % + 1.5
    0.2 % + 15
    0.2 % + 150
    (
    V
    unc
    )
    +
    (
    I
    unc
    )
    Hipot Leakage Current Mode Uncertainty
    Hipot Timer Measurement Mode
    Range
    ..........................................................................0.1 to 999 s
    Resolution
    ..................................................................1 ms
    Uncertainty
    ................................................................0.02 % + 2 ms (dc)
    0.02 % + 20 ms (ac)
    10 kV Adapter (1000:1 voltage divider)
    Range
    ..........................................................................0 to 10 kV ac peak/dc
    Resolution
    ..................................................................41⁄2 digits
    Uncertainty
    ................................................................0.3 % of value + 5 V dc
    0.5 % of value + 5 V ac at 50 or 60 Hz
    80K-40 High Voltage Probe
    Range
    ..........................................................................0 to 40 kV ac peak/dc
    Resolution
    ..................................................................41⁄2 digits
    Uncertainty
    ................................................................0.5 % of value + 10 V dc
    0.5 % of value + 10 V ac at 50 or 60 Hz