    P593 Multivalued
    decade inductance box, inductor standard set is
    analog
    of  General Radio (GR, GenRad)
    , IET Labs, but has the same or better characteristics.
    Inductance standard
    P593
    d
    esigned
    for use as an AC element in measuring systems
    with frequency of
    1 kHz
    to
    10000kHz
    .
    Standard’s
    nominal
    value
    of
    inductance
    0.01
    mkH
    -
    100mH
    Accuracy class:
    1
    ; 2; 5
    Valued Inductance standard
    P593
    (hereinafter - standard)
    are
    designed
    for use as an AC element in measuring systems
    with frequency of 1 kHz
    to
    10000kHz
    .
    Inductance standard
    P593
    designed for use
    in moderate climate conditions
    in dry
    heated rooms
    at ambient temperature
    of 10 to
    35 °
    C and relative
    humidity up to 80
    % at 25
    °
    C.
    P593  a set of:
    15 standard inductors
    ;
    Nominal value from
    0.01mkH to 100mH;
    Accuracy class:
    1, 2, 5;
    Accuracy of the attestation:
    from 0.2;
    Full average lifespan - at least
    10 years;
    Dimensions:
    100x150mm
    for more 1mkH;
    40x160mm
    for less 0,3 mkH;
    490x335x185mm
    -
    whole case;
    Weight: 1 standart -
    0,7kg;
    Whole set -
    15kg;
    Technical characteristic of Decade inductance box inductor standard set type P593:
    Nominal
    Value of inductance
    Accuracy
    class
    Normal
    Frequency
    KHz
    Max
    Current
    A
    Max
    Voltage
    V
    Q
    Q/Frequency
    KHz
    100 mH
    1
    1
    0,010
    5,000
    70
    30
    30 mH
    1
    1
    0,010
    1,000
    40
    30
    10 mH
    1
    1
    0,010
    0,500
    130
    100
    3 mH
    1
    1
    0,010
    0,100
    160
    100
    1 mH
    1
    1
    0,010
    0,050
    200
    300
    300 mkH
    1
    1
    0,010
    0,020
    140
    300
    100 mkH
    1
    1
    0,010
    0,005
    200
    1000
    30 mkH
    1
    1
    0,250
    0,050
    130
    1000
    10 mkH
    1
    1
    0,250
    0,020
    210
    3000
    3 mkH
    1
    100
    0,250
    0,500
    180
    3000
    1 mkH
    2
    100
    0,250
    0,100
    200
    10000
    0,3 mkH
    2
    100
    0,500
    0,050
    -
    -
    0,1 mkH
    2
    100
    0,500
    0,020
    -
    -
    0,03 mkH
    5
    100
    0,500
    0,005
    -
    -
    0,01 mkH
    5
    100
    0,500
    0,002
    -
    -
    Technical characteristics
    Inductance standard
    P593
    correspond to GOST
    21175
    .
    Inductance
    standard
    nominal
    value
    (L),
    accuracy classes
    (K)
    , normal
    frequency
    (f),
    attestation fixed-
    frequencies
    ,
    maximum current
    values
    (I),
    maximum
    operating voltage
    values  (U),
    lowest values
    quality factor
    (Q) for
    frequencies f
    shown in
    Table 1.
    Acceptable basic error limit
    , shown
    in percentage of
    standard’s
    inductance nominal value is equal to
    accuracy class at following
    normal conditions
    :
    ambient temperature
    (20 ±
    5) °
    C;
    relative
    humidity (
    65 ±
    15)
    %;
    normal frequency
    ;
    current value is
    not more than maximum
    with
    curve sinusoidal
    form
    and distortion coefficient do not exceed 5%
    ;
    no external
    electric and magnetic fields
    , except Earth
    field
    .
    Standard accuracy
    attestation
    at inductance
    with
    above requirements
    is
    shown
    in Table 2
    ,
    under condition
    when frequency
    deviation is not more than
    ± 0.5%.
    Determination
    quality factor
    Error (δ)
    in percentage or
    AC
    resistance
    (Δ)
    in Ohm
    considering
    normal conditions
    (
    above)
    does not exceed:
    δ = ± (0.005 Q +
    2)
    (1)
    Δ = ± (0.02 R + 0.001), (
    2)
    where Q –
    standard
    measured quality factor
    R -
    standard measured resistance
    AC
    , Ohm.
    Standard
    P593
    quality factor
    is
    calculated by the formula
    :
    Q = (2π • f • L) / R, (
    3)
    where f - measurement frequency in Hz
    ;
    L -
    the measured inductance value
    , H.
    Inductance standard
    P593
    additional accuracy error caused by ambient temperature deviation from specified in normal conditions to any temperature in working temperature range, does not exceed every 10 ° C of temperature changes than half of maximum permissible basic error.
    Inductance standard
    P593
    AC or quality factor resistance changes, caused by ambient temperature deviation from specified in normal conditions to any temperature in working temperature range, does not exceed every 10 ° C of temperature changes, expressed by dependencies: ± (0.06 R + 0.001) Ohm; ± 0.06 Q.
    Standard’s
    P593
    own capacity with nominal inductance values is
    over 1mkH and do not exceed 15pF. Dimensions, mm, do not exceed:
    diameter 100, height 150 - for L ≥ 1mkH;
    diameter 40, height 160 - for L ≤ 0.3 mkH;
    490 x 335 x 185 - suitcase for packing.
    Each standard weight does not exceed 0.7 kg.
    Standard P593 set weight with suitcase does not exceed 15 kg.
    This price is for the whole set of 15
    standard inductors. NOT for one standard inductor.
    If you need only some part from this set please contact me. I will try to help you.
    This device was also used in USSR and Russia army. So it has best quality
    ,
    longevity and permanence characteristic.
    Condition:
    used (
    cosmetic defects, scratches
    ). Tested and 100% workable.
    If necessary, we can provide calibration certificate from Government standardization institute
    (+145-265usd).
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Please take a look on my other items!
    If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.
    The accuracy of the attestation of each standard inductor from set:
    Nominal
    Value of inductance
    Inductance error in % at frequency
    normal
    1;3;10;kHz
    30;100;300;
    1000kHz
    3000; 10000 kHz
    1kHz
    100kHz
    100-30 mkH
    0,20
    -
    0,20
    0,30
    -
    10 mkH
    0,20
    -
    0,20
    0,30
    1
    3 mkH
    -
    0,20
    0,20
    0,30
    1
    1 mkH
    -
    0,40
    0,20
    0,30
    1
    0,3 mkH
    -
    0,40
    0,40
    0,40
    1
    0,1 mkH
    -
    0,40
    0,50
    0,60
    1
    0,03 mkH
    -
    1,00
    1,20
    1,30
    2
    0,01 mkH
    -
    1,00
    3,20
    3,20
    4
    Technical characteristics:
    Temperature
    +10 - +35 ° C;
    Relative humidity
    50 - 75%;
    Atmospheric pressure
    84-106,7 kPa (630-800 mmHg);
    These devices also can named:
    P594, P-
    594, P
    594, R593, R 594, R-594, р 594, р
    594, р-
    594,
    inductance
    s
    tandard, standard inductor, Laboratory standard, high precision inductor, inductance box,inductance.
    Photos
    If necessary we can take photos of a device from various angles.
    Technical Documentation
    In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me.  I will look through the technical documentation for the device and I will be happy to consult you.
    Also I may speak directly with the manufacturer and find out more specific information about this product.
    If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.
    On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.
    In addition, translation of technical documentation into the customer’s language may be discussed.
    Delivery set
    On delivering the device will be completely ready for use.
    There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.
    Before sending a device, all devices are checked whether they comply with all technical specifications.
    Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages.
    I ship only fully working devices complying with all parameters.
    The warranty for this device is 1 year from the date of shipment from my warehouse.
    Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.
    When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair.
    Packaging
    Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.
    If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.
    A special handle will be made for ease of transportation.
    Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.
    Shipping details:
    Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.
    I send goods via AirMailpost.
    App. delivery time :
    Europe – 7-15 days;
    USA, Japan&others – 10-20 days (depends on a country).
    I will ship in 10-15 business days after payment clearance.
    The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.
    With express delivery you will mostly receive your goods within 3-7 working days.
    Payment details:
    I expect payment in 4 days after the auction ends.
    I accept a PayPal payment as the safest way of payment (preferably).
    If you do not have a PayPal account you can pay by wire transfer to my credit card.
    Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.
    (This will be an official purchase on eBay).
    Please, tell me if you cannot pay in time, we can always negotiate it.
    When purchasing a few items, you’ll save on shipping.
    Return policy:
    I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.
    I will refund your costs or send you the other item, as you wish (
    after I receive the previous item
    ).
    Please only serious bidders!